Signal Channel
Voltage Inputs
Modes A only, B only or Differential (A-B)
Full-scale Sensitivity Range AC measurement mode: 10 礦 to 1 V rms in a 1-2-5 sequence;
DC measurement mode 1 mV to 1 V in a 1-2-5 sequence
Input Impedance 10 MW // 30 pF
Maximum Safe Input 30 V pk-pk
Voltage Noise 5 nV/?/font> Hz at 1 kHz
CMRR > 100 dB at 1 kHz degrading by 6 dB/octave
Frequency Response AC measurement mode: 300 mHz to 60 kHz
Gain Accuracy 0.2 % typ, 0.6% max.(full bandwidth)
Distortion -90 dB THD (60 dB signal channel gain, 1 kHz
Grounding BNC shields can be grounded or floated via 1 kW to ground
Current Inputs
Full-scale Sensitivity 10 pA to 1 礎(chǔ) in a 1-2-5 sequence
Input Impedance < 250 W at 1 kHz
Maximum Safe Input 30 V pk-pk
Voltage Noise 130 fA/?/font> Hz at 1 kHz
Frequency Response AC measurement mode: 300 mHz to 60 kHz
Gain Accuracy ?/font> 0.6 % typ
Grounding BNC shields can be grounded or floated via 1 kW to ground
Line Filter
Type Two cascaded analog second-order frequency rejection (notch) stages, set to center frequencies equal to the line frequency (F) and twice the line frequency respectively
Settings F, 2F, F&2F or disabled
Frequency Rejection Each stage gives greater than 34 dB attenuation at ? % of center frequency
Main ADC
Type 18 bit ADC
Sampling Rate 200 kHz
Digital Filter
Type Two cascaded second order digital filter stages giving an overall fourth-order response.
Settings Bandpass, Low-pass or Flat
Controls
Bandpass Center Frequency: 1.000 Hz to 60 kHz;
Q-factor: 2 to 100 in a 1-2-5 sequence
Low-pass -3dB Frequency: 10 Hz to 28 kHz
Flat None
True RMS - DC Converter & Output Processor
Description True RMS algorithm implemented using a DSP running at a 200 kHz sampling rate and managed by a powerful 68000-series host processor
Output Zero Stability Digital Outputs: No zero drift on all settings;
Displays: No zero drift on all settings:
Analog Outputs: < 5 ppm/篊
Output Smoothing Time Constant: 5 ms to 10 s in a 1-2-5 sequence;
Slope: 6 or 12 dB/octave
Offset Auto and Manual offset of up to ?00 % of the full-scale sensitivity range applied prior to the RMS-DC conversion
Auxiliary Inputs
ADC 1 and 2
Maximum Input 0 V
Resolution 1 mV
Accuracy 5 mV at full-scale
Input Impedance 1 MW // 30 pF
Sample Rate ADC 1 only: 40 kHz max;
ADC 1 and 2: 13 kHz max
Trigger Mode Internal, External or burst
Trigger input TTL compatible Outputs
Signal Monitor
Amplitude 0 V FS
Impedance 1 kW
Filter Output
Function Representation of input signal after filtering by digital filter stage
Amplitude ?0 V (100% = ?/font> 5.0 V in bandpass mode)
Update Rate 200 kHz
Output Bandwidth (-3dB) 25 kHz
Output Impedance 1 kW
DC Output
Function OUTPUT, dB OUTPUT, RATIO, LOG RATIO or USER EQUATION
Amplitude ?0 V full scale
Impedance 1 kW
Update Rate 200 Hz
Auxiliary D/A Output 1, 2, 3 & 4
Max Output ?0 V
Resolution 1 mV
Impedance 1 kW
8-bit Digital Output 8 TTL compatible lines that can be independently set high or low to activate external equipment
Power - Low Voltage ?5 V at 100 mA rear panel DIN connector for powering SIGNAL RECOVERY preamplifiers
Data Storage
Data Buffer
Size 32k 16 and 32-bit data points, may be organized as 1?/font> 32k, 2?/font> 16k, 3?/font> 10.6k, 4?/font> 8k, etc.
Max Storage Rate From NRV: up to 800 16-bit values per second;
From ADC1: up to 40,000 16-bit values per second
Interfaces RS232, IEEE-488. A second RS232 port is provided to allow "daisy-chain" connection and control of up to 16 units from a single RS232 computer port.
Power Requirements
Voltage 110/120/220/240 VAC
Frequency 50/60 Hz
Power < 40 VA
Dimensions
Width 350 mm (13.75")
Depth 415 mm (16.5 ")
Height
with feet 105 mm (4.1 ")
without feet 91 mm (3.6 ")
Weight 8.1 kg (18 lbs)